Part Number Hot Search : 
2RS480T 01200 SM8LC24 LVC2G0 M5700607 066LF N74AC 10120
Product Description
Full Text Search
 

To Download KBU405G Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  - 658 - kbu401g thru kbu407g single phase 4.0 amps. glass passivated bridge rectifiers voltage range 50 to 1000 volts current 4.0 amperes features ul recognized file # e-96005 glass passivated junction ideal for printed circuit board reliable low cost construction plastic material has underwriters laboratory flammability classification 94v-0 surge overload rating to 150 amperes peak high temperature soldering guaranteed: 260 o c / 10 seconds / .375?, (9.5mm) lead lengths at 5 lbs., (2.3kg) tension weight: 0. 3 ounce, 8.0 grams mounting torque: 5 in. lbs. max. kbu dimensions in inches and (millimeters) maximum ratings and electrical characteristics rating at 25 ambient temperature unless otherwise specified. single phase, half wave, 60 hz, resistive or inductive load. for capacitive load, derate current by 20% type number symbol kbu 401g kbu 402g kbu 403g kbu 404g kbu 405g kbu 406g kbu 407g units maximum recurrent peak reverse voltage v rrm 50 100 200 400 600 800 1000 v maximum rms voltage v rms 35 70 140 280 420 560 700 v maximum dc blocking voltage v dc 50 100 200 400 600 800 1000 v maximum avera g e forward rectified current @t a = 50 i (av) 4.0 a peak forward surge current, 8.3 ms single half sne-wave superimposed on rated load (jedec method ) i fsm 150 a maximum instantaneous forward voltage @ 4.0a v f 1.1 v maximum dc reverse current @ t a =25 at rated dc blocking voltage @ t a =125 i r 5.0 500 ua ua typical thermal resistance (note 1) (note 2) r ja r jl 19 4.0 /w operating temperature range t j -55 to +150 storage temperature range t stg -55 to + 150 note: 1. units mounted on p.c.b. with 0.5 x 0.5? (12 x 12mm) copper pads and 0.375? (9.5mm) lead length. 2. units mounted on a 2? x 3? x 0.25? al. plate.
- 659 - ratings and characteristic curves (kbu401g thru kbu407g) fig.4- typical reverse characteristics per bridge element instantaneous reverse current .( a) 0 20 40 60 80 100 120 140 0.1 1 10 100 percent of rated peak reverse voltage. (%) tj=125 c 0 tj=25 c 0 fig.3- typical instantaneous forward characteristics per bridge element instantaneous for ward current . (a) .7 .6 .8 1.0 .9 1.1 1.2 1.3 0.1 0.4 4.0 40 2.0 20 0.2 1.0 10 100 instantaneous forward voltage. (v) tj=125 c 0 8.3ms single half sine wave fig.1- maximum non-repetitive forward surge current per bridge element peak for ward surge current . (a) 10 5 2 150 20 100 25 125 75 150 50 100 175 number of cycles at 60hz 8.3ms single half sine wave fig.2- maximum forward current derating curve average for ward current . (a) 50 0 100 150 0 3 2 1 4 5 ambient temperature. ( c) o mounted on 4x4 inch copper pc board 0.5"(12.7mm) lead length


▲Up To Search▲   

 
Price & Availability of KBU405G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X